Grand Meyer self-regulating cable 25W/m UHC-25
Grand Meyer® UHC-25
Self-regulating heating cable of a parallel type for universal use for freezing protection and maintaining the set temperature of pipelines and tanks that are not subjected to steaming, including in hazardous areas, as well as for heating various elements of roofing and drainage systems.
The Grand Meyer self-regulating heating cable type UHC-25 is an electrical tape heater with parallel conductors. A semi-conductive self-adjusting matrix is applied to tin-plated copper bars (1.0mm²) consisting of a large number of stranded wires. The heat-releasing element of the heating cable is the matrix itself, which changes the heat release depending on the ambient temperature.
Two layers of internal insulation applied to the fuel matrix provide dielectric resistance, moisture resistance, impact and abrasion resistance, and chemical protection to the fuel matrix. The first layer of internal insulation is made using a unique patented technology by co-extrusion with a matrix onto conductive conductors and forms a single whole with it.
The cable is protected by a wire screen, which provides mechanical protection for the fuel matrix and ensures reliable grounding along the entire length of the cable.
Pipeline heating – used to prevent icing in pipelines. The cable is placed on the pipeline with aluminum adhesive tape and covered by pipe isolation. Can be used to install into pipeline using HCF coupling.
Roof & Gutter defrost – used to prevent icing on gutters and roofs. . The cable is placed on open areas such as roof and gutter. There are many ways to fix cable on roof, depending on it’s type. For more information please contact our project dept.
Floor heating — used for heating tile, stone and marble floors in bathrooms, kitchens, foyers, lobbies. As well can be used as heat-loss replacement in cold spaces, such as garages, loading docs, balconies and other. The cable is typically maintain into thick mortar or concrete.
Radiant space heating — used as primary space heating for rooms with concrete floors. The cable is typically maintain into thick mortar or concrete.
Freezer frost heave prevention — used to prevents heaving in soils under freezers, refrigerated warehouses, and any type of cold rooms. The cable is placed in the subflooring or in conduit buried in soil.
Other ways to use self-regulating heating cable – Cable can be used for tanks that are not subjected of steaming, fire protection systems, systems for supplying technical fluids, condensate return lines, soil heating and others. For more information please contact our project dept.
* The layer is made using a unique patented technology by co-extrusion with a matrix onto conductive wires and forms a single whole with it.